InspectAPedia®   -   Search InspectApedia

InspectAPedia®

FREE Encyclopedia of Building & Environmental Construction, Diagnosis, Maintenance & Repair

The accuracy & trustworthiness of every article or Q&A is researched by human experts. See WHO ARE WE?

Question? Just ask us!

Google
InspectAPedia
  • HOME
  • SEARCH
  • AGE OF BUILDING +
    • A/C AGE
    • AIR CONDITIONER
    • ARCHITECTURE
    • BUILDING AGE
    • DOOR HARDWARE
    • ELECTRICAL
    • FLOORING
    • FOUNDATION
    • FRAMING
    • HEATER
    • HISTORIC BUILDINGS
    • INSULATION
    • KIT HOMES
    • LOG CABINS 
    • NAILS SPIKES BOLTS
    • PLASTER
    • PLUMBING
    • ROOF
    • SAW & AXE CUTS
    • SEPTIC
    • WATER HEATER
    • WINDOW HARDWARE
  • AIR CONDITIONING +
    • AIR FILTERS
    • AIR HANDLER
    • BLOWER FAN
    • COMPRESSOR
    • CONTROLS
    • DIAGNOSE & FIX
    • DUCTS
    • EVAPORATIVE COOL
    • HEAT PUMP
    • MANUALS & PARTS
    • REFRIGERANT
    • SPLIT SYSTEM
    • THERMOSTATS
    • WINDOW / WALL A/C
  • APPLIANCES +
    • CLOTHES DRYER
    • COFFEE MAKER
    • DISHWASHER
    • DOORBELL
    • EFFICIENCY
    • EXHAUST FAN
    • GARBAGE DISPOSER
    • GAS FIREPLACE
    • MICROWAVE
    • OVEN
    • RANGE
    • REFRIGRATOR
    • THERMOCOUPLE
    • THERMOSTATS
    • TRASH COMPACTOR
    • VACUUM CLEANER
    • WASHING MACHINE
  • ARCHITECTURE +
    • ARCHITECTURE ID - home
    • ARCHITECTURE STYLE, AGE
    • BATH DESIGN
    • BUILD YOUR DREAM HOME
    • DEFINITIONS
    • DICTIONARY
    • HISTORIC & OLD BUILDINGS
    • HOUSE PARTS
    • KIT HOMES
    • KITCHEN DESIGN
    • MANUFACTURED HOME
    • MOBILE HOME
    • MODULAR HOME
    • ROOF STYLE
    • WINDOWS
  • BUILDING CODES +
    • ACCESS
    • CHIMNEYS
    • CLEARANCES
    • CRAWL SPACE
    • DANGEROUS CONDITIONS
    • ELECTRICAL
    • ELEVATOR & STAIRLIFT
    • FIRE RATING
    • FRAMING TABLES, SPANS
    • GRABRAIL GRAB BAR
    • GUARDRAIL
    • HANDRAIL
    • LIGHTING
    • MOBILE HOME
    • RAILINGS
    • ROOFS
    • SAFETY
    • STAIRS
    • SEPTIC & SEWAGE
    • VENTILATION
  • CHIMNEYS +
    • ABANDONED
    • BRACKET / GALLOWS
    • CAP
    • CLEARANCES
    • CRACKS
    • DIRECT / SIDE WALL
    • DRAFT
    • FIREPLACE
    • FLUE
    • HEIGHT
    • INSPECTION
    • MASONRY
    • METAL
    • REPAIR
    • STAINS & LEAKS
    • UNLINED
    • WOOD STOVE
  • DAMAGE ASSESS +
    • ANIMALS
    • BRICK
    • CAR, FLOOD
    • CONCRETE
    • CRAWL SPACE
    • DISASTER
    • DRINKING WATER
    • DUCTS
    • EARTHQUAKE
    • ELECTRICAL
    • FIRE
    • FLOOD
    • HEAT
    • HURRICANE
    • MOLD
    • ROOF
    • SINKHOLES
    • STRUCTURE
    • WATER HEATER
    • WELL
    • WILDFIRE
    • WIND
  • ELECTRICAL +
    • AMPS VOLTS
    • BULBS
    • CAPACITORS
    • CLEARANCES
    • DEFINITIONS
    • ELECTRIC MOTOR
    • ELECTRICAL BOX
    • ELECTRICAL CODE
    • ELECTRICITY LOSS
    • FLICKERING LIGHTS
    • GENERATORS
    • LOW VOLTAGE
    • METERS
    • OLD HOUSE
    • PANEL
    • SAFETY
    • SERVICE ENTRY
    • TURN ON
    • WIRING
  • ENERGY +
    • AIR LEAKS
    • BASEMENT
    • BIO-FUEL
    • BLOWER DOORS
    • DUCTS
    • ENERGY SAVING PRIORITY
    • ENERGY USE MONITOR
    • HEAT COST SAVINGS
    • ROOF COLOR
    • R U & K VALUE
    • SEER RATING
    • SOLAR
    • TIMERS
    • VENTILATION
    • WATER HEATER
    • WIND
    • WINDOWS
  • ENVIRO-HAZARDS +
    • AIR POLLUTANTS
    • ALLERGENS +
    • ARSENIC
    • ASBESTOS
    • BACTERIA, MOLD, POLLEN
    • BEDBUGS
    • BIOLOGICAL POLLUTANT
    • CELL PHONE
    • DISINFECTANTS
    • ELECTROMAGNETIC
    • FIBERBOARD
    • FIBERGLASS
    • FORMALDEHYDE
    • GAS DETECTION
    • HAZARD vs RISK
    • HOUSE DUST
    • INDOOR AIR QUALITY
    • MOLD
    • NOISE
    • ODOR
    • OIL TANKS
    • PESTICIDE
    • SEWAGE
  • EXTERIORS +
    • BRICK
    • DECK & PORCH
    • DOORS
    • FLASHING
    • HOUSEWRAP
    • LIGHTNING
    • PAINT
    • RAMPS
    • SIDING
    • SLIP TRIP & FALL
    • STAIRS
    • WINDOWS & DOORS
  • HEATING +
    • AIR FILTERS
    • AIR HANDLER
    • BASEBOARD
    • BOILERS
    • CLEARANCES
    • CONTROLS
    • DATA TAGS
    • DIAGNOSE & FIX HEAT
    • DUCTS
    • ELECTRIC
    • FURNACES
    • GAS BURNERS
    • HEAT PUMPS
    • HEAT WON'T TURN OFF
    • HEAT WON'T TURN ON
    • MANUALS
    • MOBILE HOME
    • OIL BURNERS
    • RADIANT HEAT
    • STEAM
  • HOME INSPECTION +
    • ADVANCED METHODS
    • DISASTERS
    • DUST
    • FEAR-O-METER: Dan's 3 D's SET REPAIR PRIORITIES
    • FIBER & HAIR
    • FIBERGLASS
    • FIRE OFF-GAS
    • FORENSIC
    • GAS TEST
    • INSECTS
    • LIGHT, FORENSIC USE
    • MICROSCOPY
    • OLD BUILDINGS
    • STRUCTURE
    • THERMAL EXPANSION
  • INDOOR AIR IAQ +
    • AIRBORNE PARTICLE
    • ALLERGENS
    • CARBON DIOXIDE
    • CARBON MONOXIDE
    • CARPETS
    • CATS
    • COMBUSTION GAS
    • DUST
    • EMERGENCY RESPONSE
    • FIBERGLASS
    • HUMIDITY
    • IAQ
    • MOLD
    • ODORS
    • VENTILATION
  • INSULATION +
    • ASBESTOS
    • CHOICES
    • CRAWL SPACE
    • FIRE-BLOCK
    • HEAT LOSS
    • IDENTIFICATION
    • INSPECTION
    • LOCATION
    • R-VALUES
    • RADIANT BARRIER
    • SOUND CONTROL
  • INTERIORS +
    • CABINETS
    • CARPETS
    • CONDENSATION
    • COUNTERTOPS
    • DRYWALL FIBERBOARD
      PLASTER
    • FINISHES
    • FIREPLACE
    • FLOOR TYPES & DEFECTS
    • MOISTURE CONTROL
    • PAINT
    • SLIP TRIP & FALL
    • STAIR CONSTRUCTION
    • STAIN DIAGNOSIS
    • TILE
    • TRIM
    • WALLS
    • WOOD STOVE
  • MOBILE HOMES +
    • CODES & MANUALS
    • COOLING
    • CRAWL SPACE
    • CROSSOVER CONNECTORS
    • DATA TAGS
    • ELECTRICAL
    • EMERGENCY EXIT
    • HEATING
    • INSPECTIONS
    • INSULATION
    • LEAKS
    • MODULAR
    • PLUMBING
    • ROOF
    • SAFETY
    • SKIRTING
    • WATER HEATER
    • WIND RATING
  • MOLD +
    • ACTION GUIDE
    • AIRBORNE MOLD
    • BLACK MOLD
    • BLEACH MOLD
    • BOOK MOLD
    • EMERGENCY RESPONSE
    • FOXING STAINS
    • MILDEW
    • MOLD CLEANUP
    • MOLD DOCTORS
    • MOLD EXPERTS
    • MOLD EXPOSURE
    • MOLD PREVENTION
    • MOLD ILLNESS
    • MOLD SAMPLING
    • MOLD TEST
    • SMELLS
    • OZONE TREATMENT
  • NOISE +
    • BANGING BOOMING
    • ELECTRICAL
    • FAN
    • HEATING SYSTEM
    • HVAC SYSTEM
    • PLUMBING
    • RELAY SWITCH
    • ROOF NOISE
    • SOUND CONTROL
    • TEMPERATURE CHANGE
  • ODORS +
    • AIR CONDITIONING
    • ANIMAL or URINE
    • CAR ODORS, ANIMALS
    • FLOOR DRAIN / TRAP
    • METHANE & SEWER GAS
    • MOLD
    • HEATING SYSTEM
    • PLUMBING
    • SEPTIC SEWER
    • ODOR SENSITIVITIY
    • OZONE TREATMENT
    • SMELL PATCH TEST
    • URINE ODOR
    • WATER ODOR
  • PLUMBING +
    • AIR DISCHARGE
    • ANTI SCALD
    • CHECK VALVE
    • CLEARANCE DISTANCE
    • CLOGGED DRAIN
    • CLOGGED PIPE
    • FREEZE PROTECT
    • GAS TANK & PIPING
    • OIL TANK & PIPING
    • PLUMBING TRAPS
    • PLUMBING VENTS
    • PUMPS
    • RELIEF VALVES
    • SEPTIC SYSTEMS
    • SEWAGE PUMPS
    • TOILETS
    • WATER HEATERS
    • WATER PRESSURE
    • WATER PUMPS & WELLS
    • WATER SOFTENERS
    • WATER PIPING
    • WATER TANK
    • WINTERIZE
  • ROOFING +
    • CLEANING
    • COLOR
    • CONTRACTOR
    • FELT UNDERLAYMENT
    • FIRE RATINGS
    • FLASHING
    • HAIL
    • ICE DAM
    • INSPECTION
    • LEAK REPAIR
    • MATERIALS, AGE, TYPES
    • SEALANTS & MASTICS
    • SLOPE
    • STAINS
    • STANDARDS
    • WALKABLE
    • WARRANTIES
    • WIND DAMAGE
    • WIND NOISE
  • SEPTIC +
    • AGE
    • BACKUP PREVENT
    • BUYERS GUIDE
    • CLEARANCES
    • CLOGGED DRAIN
    • CLOGGED DRAINFIELD
    • CODES
    • COMMERCIAL
    • COMPONENT LOCATIONS
    • DESIGN ALTERNATIVES
    • DESIGN BASICS
    • DRIVING OVER
    • FAILURE SIGNS
    • FILTERS
    • FLOODED SYSTEM
    • FREEZE PROTECTION
    • HOW SEPTIC SYSTEMS WORK
    • LIFE EXPECTANCY
    • LOADING & DYE TEST
    • MAINTENANCE
    • ODORS, SEWER GAS
    • PLANTS OVER
    • PUMPS
    • REPAIR
    • SAFETY
    • SELLERS GUIDE
    • SEPTIC SYSTEM TYPES
    • SEPTIC TANKS
    • SEWAGE BACKUP
  • STRUCTURE +
    • CHIMNEY REPAIR
    • CLEARANCE DISTANCES
    • COLUMNS & POSTS, DEFECTS
    • CRAWL SPACES
    • DAMAGE REPAIR
    • DECK & PORCH
    • EARTHQUAKE, FLOOD,
      DISASTER
    • FIRE ESCAPES & STAIRS
    • FOUNDATION TYPES
    • FOUNDATION REPAIR
    • FRAMING DAMAGE REPAIR
    • FRAMING METHODS, TYPES
    • MOISTURE CONTROL
    • ROOF FRAMING
    • ROT TYPES
    • SINKHOLES
    • STAIRS, RAILINGS
    • STRUCTURAL DAMAGE
    • STRUCTURE TYPES
      MATERIALS
  • VENTILATION +
    • AIR CHANGE RATE
    • AIR FLOW
    • AIR POLLUTANTS
    • ATTIC
    • BACKDRAFTING
    • BALANCED
    • BATHROOM
    • BLOWER DOORS
    • CATHEDRAL CEILINGS
    • COMBUSTION AIR
    • CONDENSATION
    • EXHAUST FAN
    • KITCHEN
    • HEAT LOSS
    • HIP ROOF
    • HOT ROOF
    • HUMIDITY
    • ICE DAMS
    • ROOF VENTS
    • SKYLIGHT VENT
    • SOFFIT VENTS
    • VENTILATION CODES
  • WATER SUPPLY +
    • CISTERNS
    • GREYWATER
    • NO WATER PRESSURE
    • ODORS
    • WATER CONSERVATION
    • WATER CONTAMINATION
    • WATER FILTERS
    • WATER METERS
    • WATER ODORS
    • WATER POLLUTANTS
    • WATER PRESSURE BOOSTER
    • WATER PRESSURE LOSS
    • WATER PRESSURE REGULATOR
    • WATER PUMP CONTROLS & SWITCHES
    • WATER PUMP REPAIR
    • WATER TANK REPAIR
    • WATER TESTS
    • WATER TREATMENT
    • WELLS CISTERNS & SPRINGS
  • EXPERTS LIST
  • ESTIMATING
  • ABOUT US
  • CONTACT US


ADVERTISEMENT



ADVERTISEMENT




ADVERTISEMENT

Photograph of water tankWater Tank Size, Volume, & Requirements

  • POST a QUESTION or COMMENT about the size of water tanks in buildings: what size do we need, what are "equivalent" water tank sizes in gallons or liters and what does that mean?

Water tank sizing charts, formulas, advice:

This article explains Water Tank Size - how much water is in the water pressure tank? We address the question of how much water volume we need to avoid short cycling the water pump?

This article series answers just about any question you may have about pumps, wells, and drinking water.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?

How Much Water is in the Water Tank? How big a tank is needed?

Water storage tank (C) Daniel Friedman

How to calculate the volume of water in a water tank

IF we just wanted to calculate the volume of water inside of a round water tank (photo at left), for simplicity ignoring a concave or convex (domed) water tank top and maybe bottom, we can use the formula to calculate the volume of a cylinder. Just measure the height and circumference of the water tank.

[Click to enlarge any image]

Reader Craig Revill send us this photograph [above] of a large water storage tank in an 80 to 100 year old home, along with the tank dimensions: 36" in diameter and 99" in length. You can use the following formula to calculate the number of gallons of water (or any other liquid) in a storage tank:

pi * radius2 * height (pi is 3.1416)

Gallons of water in a tank: one gallon = 231 cu. in. 

Reader Roger Davis reminded us to make clear that in the formula above, the radius (which is half of the tank diameter) should be squared. That is, divide the diameter in half to obtain the radius, and multiply r x r to obtain r2.

For the 36" diameter x 99" long water tank above, we calculated the water tank volume as follows:

[3.1416 x (18")2 x 99" = 100,782 cu .in.] / 231 = 436 gallons in this water tank.

That's a big tank storing a lot of water, probably indicating a well with a very low flow rate at the home where this water tank was installed. Or someone was planning to survive a long dry period. The small control connection shown at the 11 o'clock position on the end of this water tank was

an AIR VOLUME CONTROL.

Domed water tank volume: If we needed to be precise and if the bottom and top of a water tank are domed at the top and convex at the bottom (usually) we can measure these areas and calculate their volume using the formula for the volume of a sphere (or part of one).

But we suggest skipping this detail. Probably the spherical volume lost from the convex tank bottom is about equal to the spherical volume of the tank top, so it's a wash and we can just use the tank's overall height and diameter.

A 30 gallon water tank does not give you 30 gallons before the pump turns on

Photograph of a 1-line jet pump (shallow well) and water softener

How much water the tank holds or the physical volume of the water tank that is useful to know but iIt's how much water we can get out of the water tank before the pump has to turn on that is important when sizing or adjusting water supply systems and pumps.

This is the "draw down" volume, which we can measure or calculate, or we can focus instead on how long (in time) we can run the water before the pump has to turn on.

If your water pump turns on and off to frequently it can overheat or damage the pump or its controls. Usually this short cycling of the pump is not because the water tank is too small, it's because the tank has lost its air charge. See our discussion of "short cycling" water pumps

at WATER PUMP SHORT CYCLING - home . If your pump is short cycling you want to fix it, as we explain in that article.

The photograph shows a one-line jet pump, the water pressure tank, and a water softener. We know from the fact that this is a single line jet well pump that the well is a shallow one, probably less than 27' deep.

Well depth may have implications for water quantity and quality and vulnerability to surface water contamination.

Remember that a "30 gallon water tank" used to control water pressure and pump cycling in a building does not hold 30 gallons of water, but something less than that (say 20 gallons of water max and 10 gallons of air at the point of pump cut-off).

Then as you draw water out (and the in-tank pressure falls down to the pump cut-on point) the pump is going to come on before all of the water leaves the tank.

So the maximum actual water you get out of the tank is less than the tank size, maybe 15 to 20 gallons max. The bladder-type pressure tank manufacturers cite an "equivalent" draw-down water volume as that provided by the older bladderless tanks.

How to measure the draw-down water volume provided by a water tank

  • After the water pump has just shut off at full cut-out pressure (the water tank is now as full as it's going to get), put a 5 gallon bucket under a bath tub spout or other convenient faucet or hose.
  • Then turn on the water and let it run into your test bucket.
  • Listen for when the pump cuts on, or if your pump is submersible (and you can't hear the pump) station an assistant next to the pump control and have them listen for the click that indicates that the pump relay has turned on - they'll also see the pump pressure gauge start to move back up.
  • When the assistant sees or hears that condition, turn OFF the water at your test fixture.
  • Measure the volume of water in your bucket.
  • That's the draw down volume.

What are some typical water tank draw down volumes?

A 10 gallon water pressure tank that starts fully empty and is pumped up to about 50 psi will contain about 3 gallons of air and 7 gallons of water. The water tank in normal operation does not draw down to 0 gauge pressure before the pump comes on.

The water tank provides out flowing water down to 20 psi (on a 20-40 psi system or down to 30 at a 30-50 psi system) when the pump comes on.

A water pressure tank with a total volume of 10 gallons and operating between 20 psi and 50 psi of pressure will have a draw down water volume of just 4.35 gallons of water.

A typical kitchen water faucet runs between 3 gpm and 5 gpm (varying as the water pressure in the system varies as the water pump cycles on and off), so we can expect to run the water at the tap for about a minute before the pump will come on with this theoretical water tank.

Because the pressure drops as the water tank empties and then increases as the water pump comes back on, the water pressure at a faucet or other plumbing fixture will vary between the pump cut-in pressure (typically 20 psi or 30 psi) and the pump cut out cycle (typically 40 psi to 50 psi). quoting

from WATER TANK PRESSURE CALCULATIONS

The above-cited article, which we admit is a bit unnecessarily complex (I was answering someone else's query) has the math you need to calculate the actual draw-down volume of water you get with a given sized tank, with a given in-tank water volume when the pump has reached its shutoff point.

Relationship of Water Tank Rated Size to Actual Water Draw-down Volume?

Question: what is the relationship of water tank rated size to actual water draw-down volume?

How much water should be in the water pressure tank internal bladder? The water tanks are rated as 85 gallons. When the system cut-out water pressure is reached there is only about 5gal in tanks? - Stephen

Reply: Table of Water Tank Draw-Down vs Rated Size

Modern internal bladder type water pressure tanks give an "equivalent draw down" cycle to the actual "gallons" number on the equipment, but the actual physical volume of water may be significantly less.

5 Gallons does not sound reasonable. Typically on an "85 gallon" sized water tank, the actual water draw-down volume will be about 25 gallons. Below we include a table of rough estimates of actual water draw down volumes for different internal bladder water pressure tanks.

Check your water pressure tank air pre-charge. When the water tank is completely empty the air pre-charge should be 2 psi below the pump control's cut-in pressure. If the pre-charge pressure is too high that will reduce the volume of water held in your water tank.

Table of Typical Water Tank Draw-Down vs Rated Size

Water Tank Rated-Size (approximate gallons) Actual Volume of Water Draw Down (approximate gallons)
20
6
30
9
50
14
85
25
120
36

Notes to the water tank draw-down volume table above:

  1. The "actual draw down" is the physical volume of water that is drawn from the water pressure tank before we expect the pressure drop in the water supply system to reach the well pump cut-in pressure.
  2. The exact water tank size and expected draw-down water volume will vary by manufacturer and tank model, so our data above is only approximate.
  3. The significance of the "draw-down" volume of water is that it determines the frequency with which the water pump has to cycle on and off which in turn affects equipment life.

Detailed Chart of Water Pressure Tank Sizing, Water Tank Volume, Water Drawdown Volume in Gallons

Well-Rite Water Tank Model Total Water Tank Volume Equivalent
Bladderless
Water Tank Size
Drawdown Water Volume at Various Pressure Control Settings
 
20/40 psi
30/50 psi
40/60 psi
  Gals Liters Gallons Gals Liters Gals Liters Gals Liters
WR45 14 60 30 Gal 5.2 19.68 4.3 16.28 3.8 14.38
WR60 20 80 43 Gal 7.4 28 6.2 23.47 5.4 20.41
WR80 26 100 82 Gal 9.6 36.34 8.1 30.66 7 26.5
WR100 32 120 82 Gal 11.8 44.66 9.9 37.47 8.6 32.55
WR120 33 130 82 Gal 12.3 46.56 10.3 38.99 9 34.06
WR140 44 170 120 Gal 16.3 61.7 13.6 51.48 11.9 45.04
WR200 62 240 220 Gal 22.9 86.68 19.2 72.67 16.7 63.21
WR240 81 310 220 Gal 30 113.55 25.1 95 21.9 82.89
WR260 85 325 220 Gal 31.5 119.23 26.4 99.92 23 87.05
WR360 119 450 450 Gal 43.6 165.03 36.8 139.29 32.1 121.5

Notes to the Wel-Rite Water Tank Sizing Chart

Data based on a Well-Rite® water pressure tank [1]

When choosing an internal-bladder type water pressure tank, take note of the operating pressure range of your well pump equipment. You will see in the table above that the higher you set the water pressure cut-in and cut-out, the smaller will be the draw-down volume provided by a particular water pressure tank.

Inspect Your Water Supply System to See What's Installed

Even before performing water quantity, quality, equipment function tests, there is an enormous amount we can determine about a building's water supply just by looking at the equipment. Articles here provide details on water pumps, tanks, controls, and wells and water supply inspection, diagnosis, and repair.

Finding the location of your well and inspecting the condition of the well piping and equipment are an important first step to assure a functional and potable drinking water supply - that is, having enough water supply and having water that is safe to drink. The articles listed below provide detailed advice on diagnosing and repairing problems with water pumps, water tanks, wells, and other water supply equipment.


...

Continue reading at LARGE CAPACITY WATER STORAGE TANKS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see WATER TANK SIZE & VOLUME FAQs - questions and answers about choosing the right size water tank, posted originally on this page

Or see these

Recommended Articles

  • EXPANSION TANK SIZING GUIDE - tank sizing tables for expansion tanks used on hot water heating systems
  • ROOFTOP WATER TANKS
  • PLASTIC RECYCLING CODES, TANKS, TYPES where we describe health and other concerns involving plastic tanks and other containers used for water storage.
  • SEPTIC TANK SIZE - formulas for calculating the volume and size of tanks of various sizes & shapes
  • WATER QUANTITY IMPROVEMENT
  • WATER TANK RELATION to WATER PRESSURE
  • WELL YIELD IMPROVEMENT
  • WATER TANK CLEANING CODES STANDARDS
  • WATER TANK DIAGNOSIS & REPAIR - home or see WATER TANK REPAIR PROCEDURES

Suggested citation for this web page

WATER TANK SIZE & VOLUME at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

Share this article


Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to WATER SUPPLY, PUMPS TANKS WELLS & SPRINGS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification
when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.


Comment Form is loading comments...

 

IF above you see "Comment Form is loading comments..." then COMMENT BOX - countable.ca / bawkbox.com IS NOT WORKING.

In any case you are welcome to send an email directly to us at InspectApedia.com at editor@inspectApedia.com

We'll reply to you directly. Please help us help you by noting, in your email, the URL of the InspectApedia page where you wanted to comment.

Citations & References

In addition to any citations in the article above, a full list is available on request.

  • In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested

    CONTINUE READING or RECOMMENDED ARTICLES.
  • Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: info@carsondunlop.com. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.

    Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The HOME REFERENCE BOOK - the Encyclopedia of Homes and to use illustrations from The ILLUSTRATED HOME .

    Carson Dunlop Associates provides extensive home inspection education and report writing material. In gratitude we provide links to tsome Carson Dunlop Associates products and services.


ADVERTISEMENT



InspectAPedia.comHOMEABOUTASK a QUESTIONCONTACTCONTENT USE POLICYDESCRIPTIONPOLICIESPRINTPRIVACY
© 2025 - 1985 Publisher InspectApedia.com - Daniel Friedman